Established in 2001, Puyang Zhong Yuan Restar Petroleum Equipment Co.,Ltd, “RSD” for short, is Henan’s high-tech enterprise with intellectual property advantages and independent legal person qualification. With registered capital of RMB 50 million, the Company has two subsidiaries-Henan Restar Separation Equipment Technology Co., Ltd We are mainly specialized in R&D, production and service of various intelligent separation and control systems in oil&gas drilling,engineering environmental protection and mining industries.We always take the lead in Chinese market shares of drilling fluid shale shaker for many years. Our products have been exported more than 20 countries and always extensively praised by customers. We are Class I network supplier of Sinopec,CNPC and CNOOC and registered supplier of ONGC, OIL India,KOC. High quality and international standard products make us gain many Large-scale drilling fluids recycling systems for Saudi Aramco and Gazprom projects.

Certificate of Honor

CONTACT US

Customer satisfaction is our first goal!

Phone

+86 513525609655

E-Mail

rsdgj@pyzyrsd.com

Address

Road West, North Branch, Jingkai Road, Puyang City

low sand rate and pump loss calculator
Manual - Part 4 - Operation Monitoring and Maintenance
Manual - Part 4 - Operation Monitoring and Maintenance

Part Four: Operation, Monitoring, and ,Maintenance, (OM&M) Chapter 1. Applicability A. The program will apply to new and repair on-site wastewater ,systems, as specified in the On-Site Wastewater Ordinance and this Manual. B. Owners of existing ,systems, that do not include pressure distribution, subsurface

Sta-Rite Basic Training Manual
Sta-Rite Basic Training Manual

A ,pump, located 5 ft. below the surface of the water will reduce system head loss by 5 feet. This is due to the weight of the water assisting the ,pump,. Elevation - Atmospheric Pressure Atmospheric pressure on the surface of the water helps a self-priming centrifugal ,pump, to perform. The higher the elevation that the ,pump, is installed, the ...

SANDMASTER SERIES - Cannon Water Technology
SANDMASTER SERIES - Cannon Water Technology

2. Check valve must be between the ,pump, and separator. 3. Pressure switch must be between the separator and the pressure tank. 4. Any tees or diversions of ,pump, discharge flow (such as tosprinklers or other needs)should be installeda fter the separator’s outlet. Installation ,Procedures, 1. Remove plastic caps from the inlet, outlet and purge ...

Water Well Maintenance and Rehabilitation
Water Well Maintenance and Rehabilitation

The two most common methods to rehabilitate a water ,well, are: chemicals to dissolve the incrusting materials from the ,well,. physically cleaning the ,well,. Physical methods include using a brush attached to a drilling rig, high pressure jetting, hydrofracturing, and ,well, surging.

Preventive Maintenance and Troubleshooting Guidelines for ...
Preventive Maintenance and Troubleshooting Guidelines for ...

Before ,Maintenance, Inspect the following items before performing ,maintenance, to the ,pump, system: 1. Visually inspect the ,pump, system for leakage. 2. Check the pressure switch using a pressure gauge. 3. Record the pressure switch setting if available. 4. Review any system discrepancies or perceived problems in operation. 5.

Maximizing Pump Efficiency through Reduced Corrosion and ...
Maximizing Pump Efficiency through Reduced Corrosion and ...

Continued research into the processes that degrade ,pump, performance is being matched by the development of better application techniques for protective coatings. By gaining a better understanding of both the pumping process and the factors that affect it, end users can make significant improvements in their ,maintenance, strategies.

A HOMEOWNERÕS GUIDE
A HOMEOWNERÕS GUIDE

1 Inspect and ,pump, your system every three years. ... might need special care and ,maintenance,. Alternative ,systems, use ,sand,, peat or plastic media instead of soil to promote wastewater treatment. ... ,operating procedures, of your local health department. ,Systems, with switches,

Pump & Motor Division - Parker Hannifin
Pump & Motor Division - Parker Hannifin

Three Screw ,Pump, Series ,Maintenance, & Troubleshooting Manual ,Parker Hannifin, Corporation ,Pump, & Motor Division Kings Mountain, NC 28086 2 Catalog HY09-SPS1M-M1/US Transportation and Storage 2. Transportation and Storage Always protect the ,pump, against taking in water and other contaminants. Store the ,pump, in a clean, dry and relatively warm ...

MINIMUM STANDARDS FOR THE DESIGN AND CONSTRUCTION …
MINIMUM STANDARDS FOR THE DESIGN AND CONSTRUCTION …

SANITARY SEWER ,PUMP, STATION CONSTRUCTION ,PROCEDURES, 19. ,SAND,, OIL AND GREASE INTERCEPTOR 20. DETAILS . SECTION 1 ... The Department will only consider for operation and ,maintenance, water ,systems, and sanitary sewer ,systems, installed under the ... Detailed description of ,operating procedures, for the item of equipment specifically written ...

OPERATING ENGINEER ADVISORY COMMITTEE MINIMUM …
OPERATING ENGINEER ADVISORY COMMITTEE MINIMUM …

d. ,Pump,, shaft and bearing ,maintenance, and installation. 5. “Green Technology and construction, including but not limited to the philosophy and science of green technology and green building and construction techniques, green waste management, the installation of energy efficient ,systems, including solar, photo voltaic, wind and hydro ,systems,”

Products - Cosasco - Rohrback Cosasco Systems
Products - Cosasco - Rohrback Cosasco Systems

Back Pressure ,Pump,. Must be used with all Cosasco retrievers when pressure equalization is not achieved by normal ,operating procedures,. Buttweld Access Fitting Assembly Model 52. ... Safe, easy insertion and retrieval of corrosion/erosion monitoring ,systems, and preventive ,maintenance, devices.

MINIMUM STANDARDS FOR THE DESIGN AND CONSTRUCTION …
MINIMUM STANDARDS FOR THE DESIGN AND CONSTRUCTION …

SANITARY SEWER ,PUMP, STATION CONSTRUCTION ,PROCEDURES, 19. ,SAND,, OIL AND GREASE INTERCEPTOR 20. DETAILS . SECTION 1 ... The Department will only consider for operation and ,maintenance, water ,systems, and sanitary sewer ,systems, installed under the ... Detailed description of ,operating procedures, for the item of equipment specifically written ...

Operations & Maintenance
Operations & Maintenance

Operations & Maintenance, 3 Success Indicator: 3) 99% flood protection achieved for rainfall events within project design standards Definition: Percentage of time in the acceptable range. Moving water within ,operating, criteria is accomplished through 24-hour real-time

Operations Manual
Operations Manual

Citrus Peel Oil Recovery ,Systems Operations Manual, - 8 - Immiscible Incapable of being mixed together. An example is that of oil and water. Centripetal ,Pump, A type of ,pump, used as a centrifuge discharge ,pump, whereby the outer volute (casing or housing) of the ,pump, revolves while the impeller of the ,pump, …

Operations Manual
Operations Manual

Citrus Peel Oil Recovery ,Systems Operations Manual, - 8 - Immiscible Incapable of being mixed together. An example is that of oil and water. Centripetal ,Pump, A type of ,pump, used as a centrifuge discharge ,pump, whereby the outer volute (casing or housing) of the ,pump, revolves while the impeller of the ,pump, is stationary.

Gap Analysis Tool - Microsoft
Gap Analysis Tool - Microsoft

1. Understand Lockout/Tagout procedures: 2. Define important terms needed to properly execute an inspection 3. Read and analyze gauges, meters, and pumps: 4. Understand warning tag labels 5. Recognize the basic components of a pump: 6. Understand the basic functions of pump controls